language中文 English Welcomes to Hangzhou KleanAire
Hangzhou KleanAire Solutions Since 2006
Hotline:+86-571-88739099
Path: Index > Technical Support
How it Works Sizing Formula Installation Guide PDF Download

123.jpg

Sizing

Formula

■ Based on the engine intake parameters provided by the engine factory, select a pre filter that is suitable for this flow parameter;
■ If the manufacturer or user does not have relevant engine intake flow parameters, please calculate the intake volume as follows.


4 Cycle Engines
Airflow Ratings(CFM)
RPM x    (L) x   Vol.Efficiency x   61.02
2000
Required Airflow ******(CFM)  
Volumetric Efficiency
Diesel Engines Naturally Aspirated 0.85
Turbocharged 1.60
Turbocharged-aftercooled 1.85
Electronic fuel injection/air to air intercooling/td> Please consult us
Gasoline Engines Up to 2500 RPM< 0.80
2500 to 3000 RPM 0.75
3000 to 4000 RPM 0.70

CFM Formula

4 Cycle Engines

CFM = RPM x CID x Vol.efficiency
3456

CFM - Cubic Feet Per Minute
CMM – Cubic Meters Per Minute
L- Liters
RPM - Revolutions Per Minute
CID – Cubic Inch Displacement


CMM Formula

4 Cycle Engines

CMM = RPM x L x Vol.efficiency
2000

Conversion Formula for Metric Displacement to CID:
Cubic Centimeters (cm³) × 0.06102 =CID
Displacement in Liters × 61.02=CID
Conversion of CFM to CMM multiply by 0.0283

Learn more

Installation

Guide

The air precleaner is sized according to the engine airflow ratings and not according to the air intake pipe size.

The air precleaner must not be mounted flush against any surface of the equipment as clearance is needed for the discharge of debris, dirts, dust. A minimum clearance of 5cm is recommended.

For optimum results, vac valves, rubber valves on the filter canister, air intake system should be properly sealed/closed to prevent contaminated air from by-passing the precleaner.

Hump hoses are strongly recommended for air precleaner installed in high vibration applications.


Maintenance Instructions

KleanAire precleaners are self-powered & self-cleaning and it virtually requires no maintenance. However, the discharge ports should be checked periodically to ensure that it is not plugged by debris, dirt, mud (especially in moist environment)

  • #01
  • #02
  • #03

    #03

    For optimum results, vac valves, rubber valves  on the filter canister, air intake system should  be properly sealed/closed to prevent  contaminated air from by-passing the precleaner.

  • #04

PDF

Download